FIREGUARD®
Phone: (262) 534-3130     Fax: (262) 534-4748     e-mail: sales@ipstanks.com

HOME

2 Hour Fire-rated Fireguard®:

Lightweight double wall steel aboveground storage tank

 
For aboveground fuel storage, concrete tanks are good...
and heavy! They're also expensive to transport and install
and almost impossible to move once they're in place.

Fireguard® offers the safety of UL 2085 steel
secondary containment...plus lightweight convenience.

Fireguard® features a super lightweight insulation within the
interstice, reducing total tank weight by more than half--so it
can be easily relocated! The porous insulation material allows
migration of any liquid through the interstice to the monitoring
point. Unlike plastic liners, the steel double wall design provides
110% UL-listed secondary containment. And Fireguard®
comes delivered as a complete unit--with Steel Tank Institute
Quality Assurance built in. Isn't this the kind of performance
you're looking for?

FIREGUARD SPECIFICATIONS

CYLINDRICAL DESIGN

SAMPLE INNER TANK DIMENSIONS

GALLONS

LENGTH

DIAMETER

   

(inches)

 
SAMPLE OUTER TANKS
DIMENSIONS
LENGTH DIAMETER
  (inches)  
INNER & OUTER
STEEL WALL
THICKNESSES (inches)
(min.)
APPROX.
WEIGHT
(lbs.)
560 72 48 84 60 0.123 3,600
1,000 72 64 84 76 0.123 5,000
2,000 144 64 156 76 0.167 9,100
4,000 168 84 180 96 0.240 16,500
5,000 162 96 174 108 0.240 18,600
8,000 252 96 264 108 0.240 26,200
10,000 324 96 336 108 0.240 32,300
12,000 384 96 396 108 0.240 37,400
RECTANGULAR DESIGN
INNER TANK DIMENSIONS (inches)
GALLONS LENGTH WIDTH HEIGHT
  (max.) (max.) (max.)
OUTER TANK DIMENSIONS (inches)
LENGTH WIDTH HEIGHT
(max.) (max.) (max.)
INNER & OUTER
STEEL WALL
THICKNESSES (inches)
(min.)
APPROX.
WEIGHT
(lbs.)
500 90 36 36
1,000 116 56 36
2,000 128 76 48
102 48 49
128 68 49
140 88 61
0.123
0.167
0.240
4,000
7,000
12,250

Note: Consult manufacturer for exact dimensions.

IS YOUR ABOVEGROUND TANK EVERYTHING IT'S CRACKED UP TO BE?
FIREGUARD® vs. Concrete Encased

• Secondary containment is testable on-site
using standard, economical testing procedures.


• Fireguard®'s steel outer wall provides
low-cost maintenance and protects the
insulation material from weathering.


• An average 12,000 gallon Fireguard® weighs
under 30,000 pounds - well within the legal
load limit for trucking.


• 30-year warranty is standard with every
Fireguard®.

• The secondary containment on certain designs
may require elaborate and expensive
procedures to be tested on-site.

• Exposed concrete outer wall is susceptible to
cracking, spalling and weathering - problems
that are expensive to correct and are usually not
covered by warranty.

• An average 12,000 gallon concrete-encased
tank weighs upwards of 100,000 pounds -
imagine the hassles involved in handling that
tank.

• Some manufacturers may charge extra for a
30-year warranty.

 

Beware of False   
Secondary Containment

UL 2085 has two listings for thermally insulated tanks: one for single wall tanks and one for secondary containment (double wall). The most common fire protected tank models are not listed for secondary containment. Although a plastic liner may be installed between the inner steel tank and the concrete encasement, and is perceived by tank owners as secondary containment, according to UL listings, the liners do not constitute secondary containment.

The liners may provide a monitorable interstice during normal use. During a fire, liners could leak out through cracks in the concrete. If this were to occur. UL testing has not determined the consequences if the concrete insulation absorbs gasoline during a pool fire. However, a recent pool test conducted for Fireguard's® UL 2085 listing examined the consequences of gasoline in the interstice which could be absorbed by the insulation material. Testing results proved that vapors and flames vented out of the interstice and insulation material as designed. The tank integrity of Fireguard® would not be jeopardized during such a fire.

Many concrete encapsulated tanks using plastic liners are not UL 2085 listed for secondary containment--their listing only addresses the thermal insulation. Tank customers and regulators may not be aware that many UL 2085 listed tanks that appear to be double wall don't include secondary containment as part of the UL listing. Fireguard® is UL 2085 listed for secondary containment and uses a steel outer wall for the secondary containment.

Phone: (262) 534-3130     Fax: (262) 534-4748     e-mail: sales@ipstanks.com

 


[HOME]  [COMPANY PROFILE]  [PLANT CAPABILITY]  [PRODUCTS]
[ABOVEGROUND]  [HORIZONTAL & VERTICAL]  [STAINLESS STEEL]  [FLAMESHIELD]
[FIREGUARD®]  [SPECIALTY COATINGS]  [ACCESSORIES]
[ASME]  [OIL/WATER SEPARATORS]  [STI-P3®]  [SPECIALTY WELDMENTS]  [FIELD SERVICES]
[CONTACT US]

Hit Counter

PRODUCTS
ABOVEGROUND
* HORIZONTAL & VERTICAL
* STAINLESS STEEL
* FLAMESHIELD

* FIREGUARD®
* SPECIALTY COATINGS
* ACCESSORIES

ASME Pressure Tanks

OIL/WATER SEPARATORS

STI-P3®

FIELD SERVICES

SPECIALTY WELDMENTS

LOAD CELLS

Field Services, Repairs & Testing

Furnace Fans, Baskets, Mesh Products, Radiant Tubes, Retort/Hood, Muffles, etc.

Ductile Iron Casting

PLANT CAPABILITY

COMPANY PROFILE

CONTACT US

 

INTERNATIONAL
PRODUCTION
SPECIALISTS

35006 Washington Ave
Honey Creek, WI 
53105

Telephone: 
 
(262)534-3130
Fax: (262) 534-4748


e-mail us